The Application of S-Transform to Reduce Border Distortion Effect Based on Window Length
Abstract
The enhancement of powerful signal processing tools has broadened the scope research in power quality analysis.The necessity of processing tools to compute the signals accurately without border distortion effect presence has demanded nowadays. Hence, S-Transform has been selected in this paper as a time-frequency analysis tools for power disturbance detection and localization as it capable to extract features and high resolution to deal with border distortion effect. Various window length signal has been analyzed to overcome the border distortion effect in S-Transform.To ascertain validity of the proposed scheme, it is validated with IEEE 3 bus test system and simulation results show that the proposed technique can minimize the border effect while detecting transient and voltage sag during fault system. As a result, the longest window length which is four cycle, outperform the least MSE value which indicate the best performance. While, the shortest window length resulting highest MSE value which indicate the worst performance.
Keywords
Full Text:
PDFDOI: http://doi.org/10.11591/ijeecs.v9.i1.pp177-182
Refbacks
- There are currently no refbacks.
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Indonesian Journal of Electrical Engineering and Computer Science (IJEECS)
p-ISSN: 2502-4752, e-ISSN: 2502-4760