Hysteresis control of the new split-packed-U-cell inverter

Ayoub El Gadari, Hind El Ouardi, Youssef Ounejjar, Kamal Al-haddad

Abstract


The authors provide a novel hysteresis control method for the SPUC inverter in this paper. The suggested system, which consist of the SPUC inverter and the balancing algorithm can offer eleven levels at output voltage using only seven switches, a closed loop is applied to maintain capacitors voltage at desired values, another hysteresis control that ensures capacitors voltage self-balancing is implemented in open loop which result in the proposed SPUC9 inverter .No voltage sensor or filtering is needed, as a consequence the inverter and installation expenses are kept to a minimum. The authors utilized MATLAB/Simulink environment to simulate the proposed converters. Simulation results prove all the concepts given in this paper. Total harmonic distortion remains reduced and depends on the hysteresis bandwidth


Keywords


Hystetesis control; Neutral point clamped; Packed-U-cell; Split packed-U-cell; Total harmonic distortion

Full Text:

PDF


DOI: http://doi.org/10.11591/ijeecs.v28.i3.pp1345-1354

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

The Indonesian Journal of Electrical Engineering and Computer Science (IJEECS)
p-ISSN: 2502-4752, e-ISSN: 2502-4760
This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).

shopify stats IJEECS visitor statistics