Novel ripple reduction method using three-level inverters with unipolar PWM

Paiboon Kiatsookkanatorn, Napat Watjanatepin

Abstract


This paper proposes a novel method to reduce voltage and current ripple for the inverters by using three-level inverters with unipolar pulse width modulation (PWM) (3LFB-2U). A simple technique of switching signal generation by using carrier-based dipolar modulation of three-phase three-level inverters is extended to single-phase inverters that can be done by generating all possible switching patterns of the single-phase three-level inverters. Moreover, the concept of carrier-based dipolar modulation and the construction of reference voltages from desired output voltage and added zero voltage to control unipolar switching is also shown. The research results reveal that the proposed method can reduce the voltage and current ripple. Furthermore, the voltage and current harmonics can reduce by 27.80% and 1.79%, respectively less than two-level inverters without a loss of a simple modulation to generate the switching signals.

Keywords


carrier-based modulation; three-level inverters; two-level inverters; voltage and current ripple;

Full Text:

PDF


DOI: http://doi.org/10.11591/ijeecs.v22.i3.pp1272-1283

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

The Indonesian Journal of Electrical Engineering and Computer Science (IJEECS)
p-ISSN: 2502-4752, e-ISSN: 2502-4760
This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).

shopify stats IJEECS visitor statistics